USER'S MANUAL
AMBIENT AIR BREATHING
APPARATUS (AABA) PUMPS
P/N 9806
P/N 9821
P/N 9832
P/N 9833
P/N 9846
P/N 9850
Read and understand all instructions before using this product.
Open carton carefully and inspect product for damage caused by carrier.
If any damage is found, report and submit claim to carrier.
ALLEGRO
®
INDUSTRIES
P/N: UM006
Zobrazit stránku 0
1 2 3 4 5 6 ... 12 13

Shrnutí obsahu

Strany 1 - P/N: UM006

USER'S MANUAL AMBIENT AIR BREATHING APPARATUS (AABA) PUMPS P/N 9806 P/N 9821 P/N 9832 P/N 9833 P/N 9846 P/N 9850 Read and unders

Strany 2

T R O U B L E S H O O T I N G ELECTRIC MODELS: 1) If motor fails: • If motor is extremely cold. o Bring to room temperature before starting. • En

Strany 3

4) If there is a drop in outlet pressure: • Check if exhaust filter housing and canister is cross-threaded or not seated firmly onto housing gasket

Strany 4

WARRANTY Damage resulting from carrier handling abuse is not covered by product warranty. To protect your interest, inspect product immediately. Th

Strany 5

ambairpumman.doc Rev C. 07/03 11

Strany 6

TABLE OF CONTENTS PAGE NUMBER INTRODUCTION/DESCRIPTION ...

Strany 7 - (3,7kW) 0 – 15 0 – 20

INTRODUCTION This manual provides instructions for the use and maintenance of Allegro Ambient Air Breathing Apparatus (AABA) Pumps. You must read

Strany 8

S A F E T Y P R E C A U T I O N S FOLLOW ALL WARNINGS AND CAUTIONS ALL PUMPS: DO NOT place oil-less air pump in an area that cannot GUARANTEE cle

Strany 9

U S E R ’ S I N S T R U C T I O N S 1) Ensure that the pump (or inlet extension filter) is in a clean uncontaminated air environment. o If clea

Strany 10

T O L E R A N C E S A N D W A R N I N G S Allegro ambient air pumps are precision pumps that have only .0015-.003 clearance between the top of the

Strany 11

S P E C I F I C A T I O N S The table shows the maximum allowable number of tight-fitting respirators or loose-fitting hoods. MODEL NUMBER PART NO.

Strany 12

M A I N T E N A N C E FILTERS: • Change inlet filter every 200 running hours or if the pressure gauge shows a drop in pressure. • Change discharge

Strany 13

P A R T S & A C C E S S O R I E S All Models • 9700-02 Exhaust filter element (Each) • 9700-11 Pump flushing liquid • 9700-15

Komentáře k této Příručce